Understand the visual task
Examination, documentation and treatment differ. We establish which areas need general room lighting and which require specialist task lighting.
Lighting that pays off.
Clinics & Treatment Rooms
A clinical practice combines focused work with patient wellbeing. General lighting, treatment areas and waiting zones each have their own tasks.
What matters ↓THE REQUIREMENTS
Examination, documentation and treatment differ. We establish which areas need general room lighting and which require specialist task lighting.
Uncomfortable changes in brightness and glare should be considered in room design—including from a patient's lying position.
Cleaning, installation method and existing ceilings influence selection. The requirements of the particular practice area come first.
LIGHTING DESIGN & REGULATIONS
Classification follows the actual workflow, not simply the label “clinic”. Room lighting is coordinated with examination and treatment luminaires; additional medical requirements are clarified separately.
| Activity / reference surface | Illuminance | Colour rendering Rₐ |
|---|---|---|
| Low-risk medical/care activities without contact with bodily fluids, excretions or contaminated objects | 300 lx | 90 |
| Medical or care activity with increased potential hazards, for example sharp instruments or bodily fluids | 500 lx | 90 |
| Part of this activity with an increased risk | 1,000 lx | 90 |
Values apply to the stated visual task. Usage and the risk assessment determine the specific requirements.
Colour recognition may be part of the task when assessing skin, tissue and materials. We check the proposed luminaire's colour rendering against the requirements of the treatment.
A lying patient's viewpoint matters too. Directly visible bright sources may be uncomfortable, so examination, documentation and waiting areas are considered separately.
Mounting, surfaces and cleaning products must be compatible. Specification and maintenance access are checked against hygiene procedures and product documentation.
Around 4000K is a proven starting point for general lighting in clinical practices and treatment rooms. Diagnostics, tooth-shade selection and specialist treatments may have their own requirements for colour temperature, spectrum and colour rendering. We coordinate these with the use of the room and the treatment luminaires installed.
Editorially reviewed on 29 October 2026. Check which version applies to your project.
TAKE A CLOSER LOOK
General lighting complements task-specific treatment luminaires. A standard ceiling light does not replace a specialist medical luminaire.
Conversation, movement and calm treatments need different lighting atmospheres. We consider use alongside furniture and daylight.
FROM THE ROOM TO THE SOLUTION
We clarify which version is suitable using your room details and the specific product data.

Slim side-lit LED panels for even surface lighting.
instaPLAIN piastra SL (sidelit) View ↗︎
LED downlights in different sizes for demanding lighting tasks.
instaPLAIN rotondetto AERO View ↗︎
Linear pendant with downward light and additional ceiling illumination for reception counters and work surfaces.
instaDECOR chaka View ↗︎
Slim luminaire with a uniform illuminated surface, adjustable wattage and selectable colour temperature.
instaDECOR luxor View ↗︎A REAL PROJECT
See a real project: explore the office, corridor and indirect lighting at Dr. Kilimann’s dental practice.
LIGHTING THAT PAYS OFF.
Quantity, existing power and operating hours show how your electricity costs could change. Our calculator provides an initial model using your own figures.
Calculate your own payback ↗︎MORE SPACES
LET'S SHED LIGHT ON YOUR PROJECT
An entire hall. Individual workstations.
Or perhaps an initial question.
We look forward to hearing about your project.