Escape routes kennzeichnen
Illuminated exit signs show the way out. Positions and sightlines are assessed using the escape and evacuation plan.
Lighting that pays off.
Safety & Emergency Lighting
Exit signage and emergency lighting perform different tasks. We assess routes and illumination together with the existing safety concept.
What matters ↓THE REQUIREMENTS
Illuminated exit signs show the way out. Positions and sightlines are assessed using the escape and evacuation plan.
Emergency lighting supports orientation when general lighting fails. It is a separate task from signage.
Existing power supplies, monitoring and maintenance arrangements form part of the project survey. Products are selected to match the safety concept.
LIGHTING DESIGN & REGULATIONS
Exit signs show direction; emergency lighting makes routes and hazards visible when normal lighting fails. One luminaire with an emergency function does not constitute a complete emergency-lighting concept.
| Activity / reference surface | Illuminance | Colour rendering Rₐ |
|---|---|---|
| Escape route: centre line, measurement height no more than 20cm above floor/steps | at least 1lx | at least 40 |
| High-risk workplace: visual task | at least 15lx; the risk assessment is decisive | at least 40 |
Values apply to the stated visual task. Usage and the risk assessment determine the specific requirements.
ASR A2.3 requires an assessment of the escape-route situation, for example where daylight is absent or people are unfamiliar with the building. Escape-route lighting must enable safe evacuation for at least 30 minutes.
Escape routes generally require 50% output after 5 seconds and full output after 60 seconds; special and existing-installation rules must be checked. Where many people are regularly unfamiliar with the premises, 1 second may be required. At hazardous workstations, ASR A3.4 requires the necessary level within 0.5 seconds for the duration of the hazard.
Exit signs, viewing distances and sightlines are planned under ASR A1.3. Power supplies, periodic tests, documentation and control behaviour during a failure form part of the system concept.
Emergency lighting prioritises reliable recognition of routes, obstacles and safety colours; a Kelvin value alone does not ensure this. Neutral-white light around 4000K suits many white emergency luminaires. Exit signs must retain their specified green and white safety colours in emergency operation.
Editorially reviewed on 29 October 2026. Check which version applies to your project.
TAKE A CLOSER LOOK
Signage and visibility are assessed along the actual escape route.
Stairs, changes of direction and open areas are included in the specific concept.
FROM THE ROOM TO THE SOLUTION
The instaSPACE nuray is available in an emergency version for walls and ceilings. We agree the specific version and integration into your safety concept for each project, considering exit signs and other emergency lighting separately.

Version with emergency function available on request.
product and Modellvarianten View ↗︎
Emergency exit sign for wall or ceiling mounting.
instaSHIELD sign surface View ↗︎
Suspended escape sign luminaire with adjustable mounting height.
instaSHIELD sign pendant View ↗︎
Surface-mounted emergency luminaire with self-test and three hours of battery operation.
instaSHIELD guide surface View ↗︎
Recessed emergency luminaire with self-test and three hours of battery operation.
instaSHIELD guide recessed View ↗︎LIGHTING THAT PAYS OFF.
The requirements of your location come first. We then assess investment, operation and maintenance together.
MORE SPACES
LET'S SHED LIGHT ON YOUR PROJECT
An entire hall. Individual workstations.
Or perhaps an initial question.
We look forward to hearing about your project.
relatio TM GmbH
Stocken 4 · 72336 Balingen
OUR CUSTOMERS